Mts Model 506-62-72 Hydraulic Power Supply Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Hardware Mts Model 506-62-72 Hydraulic Power Supply herunter. MTS Model 506-62-72 Hydraulic Power Supply User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Product Manual

lProduct ManualModel 506.62/.72Hydraulic Power SupplySeptember 1996117730-00D

Seite 2

2-2 OperationTable 2-1. Controls and IndicatorsItem Control/Indicator Description1 Power indicator* The Power indicator lights to indicate

Seite 3 - Table of Contents

Operation 2-32.2 Operation ProceduresThis section provides the local and remote operating procedures for the506.62/.72 Hydraulic Power Supply

Seite 4 - List of Tables

2-4 OperationRemote OperationRemote controlconnector1. Turn the Source Remote/Local switch to Remote. Make sure thatthe remote control cable

Seite 5 - Introduction

Service 3-1Section 3ServiceIntroduction This section contains service information for the Model 506.62/.72Hydraulic Power Supply (HPS). It p

Seite 6 - 1.2 Specifications

3-2 ServiceTable 3-1. Maintenance ScheduleProcedure Interval SubsectionCheck output pressure on gage* dailyReplace high-pressure filter when

Seite 7

Service 3-3End Cap – Top ViewVW-G047Bair-bleedscrewunscrewsendcap2. Loosen the air-bleed screw on top of the filter housing endcap. Seethe f

Seite 8

3-4 Service3.1.1.2 Low-Pressure Filter ReplacementThe low-pressure filter element requires replacement wheneverhydraulic fluid in the HPS res

Seite 9 - Operation

Service 3-53.1.2 Hydraulic FluidRegular maintenance of hydraulic fluid maximizes the service life ofthe system and its components.Daily fluid

Seite 10

3-6 ServiceReplacing hydraulic fluid Perform this procedure to replace the hydraulic fluid. You will need aModel 590.01 Fluid Transfer Pump

Seite 11 - 2.2 Operation Procedures

Service 3-73.1.3 AccumulatorsFor more informationabout accumulatorsSee the Series 111 Accumulator product manual(MTS part number115533-XX).

Seite 12 - Remote control

© 1996 MTS Systems Corporation. All rights reserved.

Seite 13 - Section 3

3-8 Service3.2 Service AdjustmentsService overview Figure 3-2 shows the location of the service components accessed for thefollowing procedur

Seite 14 - 3.1.1 Filters

Service 3-93.2.1 Output Pressure AdjustmentHPS – Side ViewVW-G044KpressuregageDIRT ALARMback-uprelief valveCHANGEOKRefer to Figure 3-2 for th

Seite 15 - End Cap – Top View

3-10 Service3.2.2 Dual-Temperature Switch AdjustmentsDefinition The dual-temperature switch has two adjustment screws behind itsfront protect

Seite 16

Service 3-11Water controladjustment1. Ensure that the temperature gage reads below 90°F (32°C).2. Start the HPS. Turn the water control adju

Seite 17 - 3.1.2 Hydraulic Fluid

3-12 Service3.2.4 Main Pump Low-Inlet Pressure Switch AdjustmentVW-G052Adjustment knobPressure Switch(cover removed)IndicatorFigure 3-2 shows

Seite 18 - Front View

Service 3-133.3 Starter AssemblyThe starter assembly (Figure 3-3 shows the location of its components)is located behind the starter box door.

Seite 19 - DIRT ALARM

3-14 Service3.3.1 Abnormal HPS ShutdownMotor overload Sudden shutdown of the HPS may be due to circuit protection elementsin the pump motor s

Seite 20 - 3.2 Service Adjustments

Service 3-153.3.3 PLC ServiceThe PLC in the 506.62/.72 HPS starter assembly has output and inputindicators shown in the figure below. Thes

Seite 21

3-16 Service506.62/.72 Input IndicatorsInput Indicator CH0 Description0 Turns off if switch 2TAS (115°F) opens. When fluid temperature excee

Seite 22

Installation 4-1Section 4InstallationIntroduction This section provides the following installation information for theModel 506.62/.72 Hydrau

Seite 23

Table of Contents iTable of ContentsSection 1 Introduction1.1 Functional Description...

Seite 24 - Indicator

4-2 Installation4.1 Hydraulic ConnectionsThe pressure, return and drain connections are located on the HPSmanifold shown in Figure 4-2. Refe

Seite 25 - 3.3 Starter Assembly

Installation 4-34.2 Electrical ConnectionsThe HPS is operated from a three-phase electrical power source. Theoperating voltage is labeled on

Seite 26 - 3.3.2 Fuse Replacement

4-4 Installation4.2.1 Transformer WiringOne of two types of transformers is installed in the starter assembly.Check the wiring configuration

Seite 27 - 24VDC 0.3A

Installation 4-54.2.2 Input PowerElectrical connectionprocedureSee Figure 4-3 and perform the following procedure to make theelectrical conne

Seite 28

4-6 Installation4.3 Cooling Water ConnectionsSpecifications The differential pressure required between the water inlet and outletconnections

Seite 29 - Installation

Theory of Operation 5-1Section 5Theory of OperationThis section describes the hydraulic and electrical operation of Model506.62/.72 Hydraulic

Seite 30 - 4.1 Hydraulic Connections

5-2 Theory of OperationMain and superchargepumpsThe HPS uses a variable-volume pressure compensated main pump,with a pressurized (supercharge

Seite 31 - 4.2 Electrical Connections

Theory of Operation 5-3Pump protection Pump protection is provided for the main pump by the main pumplow-inlet pressure switch that turns the

Seite 32 - 4.2.1 Transformer Wiring

5-4 Theory of OperationPump motor When 1CR contacts close, the main pump motor starts, using aWye-delta start. First relay 1S energizes to c

Seite 33 - 4.2.2 Input Power

Theory of Operation 5-55.2.2 InterlocksThe HPS contains interlock circuitry to shut down the HPS whenvarious conditions occur—such as low lev

Seite 34 - VW-G055B

ii Table of ContentsSection 5 Theory of Operation5.1 Hydraulic Operation...

Seite 35 - Theory of Operation

5-6 Theory of OperationNOTE Hydraulic power supplies are often customized forspecific applications. Actual wiring may differ fromwhat is sho

Seite 36

Theory of Operation 5-7JGNB2CR1CRF1MKEBHset at 140°F (60°C)VW-C039DSet at 100ºF35 PSI1 SOL2 SOLNote:2 TAS2 PS0101010201030104010601050107over

Seite 39 - 5.2.2 Interlocks

mMTS Systems Corporation14000 Technology DriveEden Prairie, Minnesota 55344-2290 USAToll Free Phone: 800-328-2255(within the U.S. or Canada)Phone: 952

Seite 40 - VW-C039A

Introduction 1-1Section 1IntroductionDefinition The Model 506.62/.72 Hydraulic Power Supply (HPS) uses a variable-volume (pressure compensate

Seite 41 - VW-C039D

1-2 IntroductionPressure accumulation The pump-outlet pressure accumulator smooths the HPS output andprovides additional hydraulic pressure f

Seite 42

Introduction 1-3HPS specifications Table 1-2 lists the specifications for the Model 506.62/.72 HPS.Table 1-2. HPS SpecificationsParameter Mo

Seite 44

Operation 2-1Section 2Operation2.1 Controls and IndicatorsThe controls and indicators provided with the Model 506.62/.72Hydraulic Power Suppl

Kommentare zu diesen Handbüchern