Mts Multipurpose Elite Bedienungsanleitung Seite 76

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 112
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 75
ActionList= <DO on>, <DO off>, Counter 1, Counter2
Channels= 1
Channel(1)= Channel 1
Frequency= 1
Hz Count= 1 segments
Shape= Sine
Level2= 0.0 mm
Level1 Action
mm
5.0000 <DO Off>
-5.0000 Counter 1
8.0000
-8.0000
2.000 Counter2
-2.000
5.0000
-5.0000
1.0000
-1.0000 <DO On>
6.2.11.6.0 Channel Header Syntax
Following the header data definition, you must define the first control channel. After the channel definition,
you must define the channel data for that channel.
The following is an example of proper channel data syntax:
Channel(n)= channel name
Max= maximum value and units
Min= minimum value and units
Dimension=Length
Channel Header Syntax
SuggestionsCommentsKeyword
This is a required entry and must be first. The
channel name is not case-sensitive.
Names the channel; n is the
channel number.
Channel(n)=
This is an optional entry that specifies the
maximum output for the channel.
Placed in the file by the Profile
Editor and viewed with the Show
Summary button; useful for
Max=
determining an appropriate
range with which to control the
channel.
This is an optional entry that specifies the
minimum output for the channel.
Placed in the file by the Profile
Editor and viewed with the Show
Summary button; useful for
Min=
determining an appropriate
range with which to control the
channel.
76 Multipurpose Elite Test Design Guide
6.0 Creating Advanced Tests
Seitenansicht 75
1 2 ... 71 72 73 74 75 76 77 78 79 80 81 ... 111 112

Kommentare zu diesen Handbüchern

Keine Kommentare